Guide · certificates & codes

Your electrical paperwork, in English.

Electrical paperwork is full of initials, and most of it is handed over with no explanation at all. This page is the plain-English version — what each certificate and code actually means, what you should be given at the end of a job, and what any of it tells you about the state of your house. Nothing here is specific to us; it's the national standard everybody is supposed to be working to.

EICR

Electrical Installation Condition Report

A full inspection and test of an existing installation, ending in a written report that classifies everything found. It's a health check on the wiring, not a certificate for new work.

Recommended every 5 years for rented accommodation and roughly every 10 years for an owner-occupied home — and it's the document a letting agent or solicitor will ask for.

C1

Danger present

Something on the installation presents a risk of injury right now — exposed live parts, for example.

It gets made safe on the day, before we leave. You'll be told about it while we're still on site, not in an email a week later.

C2

Potentially dangerous

Not dangerous at this moment, but it could become so — a missing earth, an unsuitable protective device, damaged cable inside an enclosure.

This is the code that makes a report 'unsatisfactory'. It needs remedial work, and we'll price it separately so you can compare.

C3

Improvement recommended

It complied with the regulations in force when it was installed but wouldn't be done that way today.

A C3 on its own doesn't fail a report. It's useful information for planning, not a reason to panic or to be pressured into rewiring.

FI

Further investigation required

Something couldn't be fully assessed on the day and needs opening up or testing further before it can be coded properly.

It also makes a report unsatisfactory, so we'd rather resolve it during the inspection than leave you holding an ambiguous document.

EIC

Electrical Installation Certificate

Issued for new installations and for significant new work — a rewire, a new consumer unit, a new circuit such as a car charger or hot tub supply.

Keep it with the house paperwork. It's the proof the circuit was designed, installed and tested correctly, and buyers' solicitors do ask.

MWC

Minor Electrical Installation Works Certificate

Used for alterations and additions to an existing circuit that don't involve a new circuit — moving a socket, adding a light point.

Small job, still certificated. If someone does alteration work and hands you nothing at all, that's worth noticing.

Part P

Building Regulations, Part P

The part of the Building Regulations covering electrical safety in dwellings. Certain work in a home is notifiable to building control.

Notifiable work needs to be certified and notified properly — it's the bit that quietly matters when you come to sell.

BS 7671

The 18th Edition wiring regulations

The national standard for electrical installation in the UK. Everything we install or alter is designed and tested against it.

It's the yardstick your certificate is measured against — so 'tested to the 18th Edition' is a statement with something behind it.

RCBO

Residual current breaker with overload

A protective device that combines overload protection with residual current protection on a single circuit.

In an RCBO board, a fault on one circuit trips only that circuit. On older split-load boards, one fault takes out half the house — including the freezer.

SPD

Surge protection device

Fitted in the consumer unit to clamp transient overvoltages from lightning or switching events on the network.

We fit one as standard with a new board. It's inexpensive at the time of installation and protects everything expensive plugged in downstream.

IP65

Ingress protection rating

Two digits describing how well an enclosure resists solids and water. The second digit is the one that matters outdoors and in bathrooms.

It's why a garden fitting costs what it costs. The wrong IP rating in the wrong place is the single most common reason outdoor lights fail in their second winter.

The plain details

Everything you might reasonably want before picking up the phone, in one place.

Business
Illuminate Electrical
Based
1 Rhodesia Cottages, Gold Cup Lane, Winkfield Row, Ascot SL5 8NR
Covering
Ascot, Windsor & all surrounding areas
Speciality
Garden & external lighting design
Standard
18th Edition BS 7671
Consumer units
Full RCBO boards, SPD fitted as standard
Phone
07876 336933
Email
michael@illuminateelectrical.co.uk
Hours
Mon–Fri 9am–5pm · Sat 10am–2pm · Sun closed

Tested to BS 7671, 18th Edition

Need an EICR on a rental?